Inverter Size Calculator

Find out what size inverter you need. Enter the total watts you will run at once and the largest start-up surge, and the calculator returns the inverter size, the current it draws from the battery, and the battery cable and fuse to match.

Add up everything that will run at the same time.
Motors and compressors draw extra for a moment when they start. Leave at 0 if you have none.

2000 WRecommended inverter size

Load plus 25% headroom
1,875 W
Battery current at this load
138.9 A
Battery current at full inverter output
185.2 A
Battery cable (5 ft run)
2 AWG

Sized with 25% headroom over the running load and a surge rating taken as twice the continuous rating, which is typical for inverter chargers. Check the surge rating and the recommended cable and fuse in the manual for the model you choose.

How to size an inverter

An inverter needs to cover two things: the running watts of everything that will be on at once, and the brief start-up surge of anything with a motor or compressor. Add up the running watts, add 25% headroom so the inverter is not working at its limit, then pick the next standard size up.

The battery side is where the large currents are. An inverter is about 90% efficient, so a 1500 W load draws about 139 A from a 12 V battery. The same load draws about 69 A at 24 V and 35 A at 48 V, which is why larger inverters are usually paired with 24 V or 48 V battery banks.

The appliance figures below are typical. The label on your own appliance is the number to use.

ApplianceTypical running watts
Laptop charger60–100
12V compressor fridge (via DC)40–60
Residential fridge100–200
Coffee maker800–1,200
Microwave1,000–1,500
Induction cooktop (single)1,400–1,800
Hair dryer1,200–1,800
Rooftop air conditioner1,200–1,800

Inverter size chart

Recommended inverter size and the battery current at that load.

Running loadInverter sizeAt 12 VAt 24 VAt 48 V
300 W500 W27.8 A13.9 A6.9 A
600 W800 W55.6 A27.8 A13.9 A
1000 W1600 W92.6 A46.3 A23.1 A
1500 W2000 W138.9 A69.4 A34.7 A
2000 W3000 W185.2 A92.6 A46.3 A
2500 W5000 W231.5 A115.7 A57.9 A
3500 W5000 W324.1 A162 A81 A

Inverter sizing questions

What size inverter do I need?

Add up the watts of everything you will run at once, add 25%, and choose the next standard size. A 1500 W load calls for a 2000 W inverter; a 2000 W load calls for 3000 W.

How many amps does a 2000 watt inverter draw from the battery?

At full output, about 185 A at 12 V, 93 A at 24 V and 46 A at 48 V, including inverter losses of about 10%.

What is the difference between running watts and surge watts?

Running watts are what an appliance uses continuously. Surge watts are the short burst a motor or compressor needs to start, often two to three times the running figure. The inverter must handle both.

Should I use a 12V, 24V or 48V inverter?

Up to about 2000 W, 12 V is practical. Above that the battery current gets very high, so 24 V or 48 V keeps cables and fuses to a manageable size.