Voltage Drop Calculator
Calculate the voltage drop in a wire run for 12V, 24V and 48V DC systems and 120V or 240V AC circuits. Enter the current, the one-way length and the wire gauge to see the drop in volts and percent, the voltage left at the load, and the gauge that keeps the drop under 3%.
3.4%Voltage drop (0.41 V)
- Voltage at the load
- 11.59 V
- Power lost in the wire
- 8.2 W
- Wire ampacity
- 60 A
- Gauge for 3% drop or less
- 8 AWG
Resistance is for stranded copper at 20 °C; ampacity is for 105 °C insulated cable at 30 °C ambient. Hot conductors have slightly higher resistance, so treat the result as a close estimate.
Parts for this circuit
How voltage drop is calculated
Every wire has resistance, so some voltage is lost between the source and the load. The loss is current × wire resistance × total length, where the total length is the round trip: out on one conductor and back on the other. This calculator doubles the one-way length for you.
Voltage drop matters most on low-voltage DC systems. Losing 0.4 V is 3.4% of a 12 V supply but only 0.3% of 120 V. As a rule, keep the drop to 3% or less for chargers, inverters, electronics and anything voltage-sensitive, and to 10% or less for non-critical loads such as general lighting.
If the drop is too high, there are three fixes: use a thicker wire, shorten the run, or raise the system voltage. Moving the same power from 12 V to 24 V halves the current and cuts the percentage drop to a quarter.
Voltage drop chart: 12V, 10 ft run
Percent voltage drop for a 12 V circuit over a 10-foot one-way run of tinned copper wire.
| Wire gauge | 10 A | 20 A | 50 A | 100 A |
|---|---|---|---|---|
| 18 AWG | 11% | 22% | 54.9% | 109.9% |
| 16 AWG | 6.9% | 13.8% | 34.5% | 69.1% |
| 14 AWG | 4.3% | 8.7% | 21.7% | 43.5% |
| 12 AWG | 2.7% | 5.5% | 13.7% | 27.3% |
| 10 AWG | 1.7% | 3.4% | 8.6% | 17.2% |
| 8 AWG | 1.1% | 2.2% | 5.4% | 10.8% |
| 6 AWG | 0.7% | 1.4% | 3.4% | 6.8% |
| 4 AWG | 0.4% | 0.9% | 2.1% | 4.3% |
| 2 AWG | 0.3% | 0.5% | 1.3% | 2.7% |
| 1 AWG | 0.2% | 0.4% | 1.1% | 2.1% |
| 1/0 AWG | 0.2% | 0.3% | 0.8% | 1.7% |
| 2/0 AWG | 0.1% | 0.3% | 0.7% | 1.3% |
| 3/0 AWG | 0.1% | 0.2% | 0.5% | 1.1% |
| 4/0 AWG | 0.1% | 0.2% | 0.4% | 0.8% |
Voltage drop questions
What is an acceptable voltage drop?
3% or less for critical circuits such as inverters, chargers, DC-DC converters and electronics, and up to 10% for non-critical loads such as general lighting. On a 12 V system, 3% is 0.36 V.
How do I calculate voltage drop?
Multiply the current by the wire's resistance per foot and by the total round-trip length. Divide by the system voltage to get the percentage. For example, 20 A through 10 feet of 10 AWG (20 feet round trip) loses about 0.41 V, which is 3.4% at 12 V.
Does voltage drop depend on the system voltage?
The drop in volts depends only on current, wire size and length. But the same loss is a much larger share of a low-voltage supply, which is why 12 V systems need heavier cable than 24 V or 48 V systems for the same power.
How do I reduce voltage drop?
Use a larger wire gauge, shorten the run, or increase the system voltage. Clean, properly crimped terminals matter too, because a poor connection adds resistance of its own.