Wire Size Calculator

Work out the wire size you need from the current and the distance. Works for 12V, 24V and 48V DC systems and 120V or 240V AC circuits in RVs, boats, vans and off-grid installations, checking both how much current the wire can carry and how much voltage is lost along the run.

For AC, use the breaker or shore power rating, for example 30 A or 50 A.
From the power source to the load. The return conductor is included automatically.

10 AWGRecommended minimum wire size

Voltage drop
2.6%
Wire ampacity
60 A
Voltage at the load
116.9 V
Recommended fuse or breaker
40 A

Based on ampacities for 105 °C insulated cable at 30 °C ambient, as used in RV, marine and vehicle systems. For wiring inside buildings, follow the NEC and local code; residential cable types are rated lower.

How to choose the right wire size

Wire size depends on two things: how much current the wire carries, and how far it carries it. The current sets the minimum size so the wire does not overheat. The distance matters because every foot of wire has resistance, so a long run loses voltage before it reaches the load. This calculator checks both and returns the smallest standard AWG size that passes.

Voltage changes the answer more than anything else. The same 30 A over 50 feet needs 10 AWG at 120 V AC, but would need far heavier cable at 12 V DC, because the same voltage loss is a much larger share of a 12 V supply. That is why long DC runs, such as to a solar array or a rear battery bank, often call for a higher system voltage.

Tinned copper is the standard choice for boats and RVs because the tin coating resists corrosion, keeping resistance low for the life of the installation. Its resistance is slightly higher than bare copper, which the calculator accounts for. Aluminum conductors need a separate ampacity table and are not covered here.

Wire size for 120V circuits by amps and distance

Minimum tinned copper wire size (AWG) for 120 V AC with 3% maximum voltage drop, on 105 °C cable as used for RV and marine shore power. Distances are one way.

Current25 ft50 ft75 ft100 ft
15 A16121010
20 A1412108
30 A121086
40 A12866
50 A10864

Need DC battery cable sizes instead? See the DC wire size calculator and its 12V chart.

Wire size questions

What size wire do I need for 30 amps?

It depends on the distance and voltage. For a 30 A RV shore power run at 120 V, 10 AWG covers up to about 50 feet with 3% voltage drop, and 8 AWG is needed out to 75 feet. At 12 V DC, 30 A over 10 feet already needs 6 AWG.

What size wire for 50 amps?

At 120 V, 50 A needs 10 AWG for a 25-foot run, 8 AWG for 50 feet and 6 AWG for 75 feet. On a 12 V DC system, 50 A over 10 feet needs 4 AWG.

Does a longer run need a thicker wire?

Yes. Voltage drop grows with length, so a longer run needs a larger conductor to deliver the same voltage at the load, even if the current stays the same.

Is AWG the same as wire gauge?

Yes. AWG (American Wire Gauge) is the standard gauge system in North America. Smaller numbers are thicker wires, and sizes above 1 AWG continue as 1/0, 2/0, 3/0 and 4/0. Use the wire gauge calculator to see what a specific gauge can carry.